Condition Possible Cause Correction
Machine does not raise (to trans- Circuit breaker open. Reset circuit breaker. Find cause
port position). for open circuit breaker and cor-
rect. Replace circuit breaker if
faulty.
Lift/Lower switch faulty.
Test switch and replace if faulty.
Lift UP relay faulty.
Test relay and replace if faulty.
Ignition key switch faulty.
Test ignition switch and replace if
faulty.
Loose or broken wire in lift up cir-
Check all wiring and connections
cuit.
and repair as necessary.
Linear actuator faulty.
Test actuator and repair or re-
place if faulty.
Linear actuator continues to oper-
Lift limit switch faulty. Make sure switch is installed
ate (but should not) after machine
properly. Test switch and replace
is lowered to aerate position.
if faulty.
Troubleshooting Page 5 - 12 HydroJect