Rev. F76.2
Reelmaster 6500-D/6700-DHydraulic System Page 4 -
1. Solenoid valve (S3)
2. Solenoid coil (8 used)
3. Solenoid coil
4. Solenoid valve (S2)
5. Solenoid blocking valve (6 used)
6. Flow control valve (5 used)
7. Flow control valve (2 used)
8. Solenoid coil spacer
9. Lift manifold block
10. Orifice (.063)
11. Straight fitting (3 used)
12. NWD--6 plug
13. Solenoid valve (S1)
14. Orifice (.100)
15. 90
o
hydraulic fitting
16. Nut
Figure 50
(Lift Manifold For R M6700--D Units With Serial No. Above 280000000)
4
6
7
5
3
2
1
2
13
2
2
8
2
5
11
10
10
11
6
14
15
11
12
25 ft--lb
(33 N--m)
20 ft--lb
(27 N--m)
25 ft--lb
(33 N--m)
25 ft--lb
(33 N--m)
20 ft--lb
(27 N--m)
20 ft--lb
(27 N--m)
10 ft--lb
(14 N--m)
48 to 60 in--lb
(5.4 to 6.7 N--m)
10 ft--lb
(14 N--m)
20 ft--lb
(27 N--m)
9
16
48 to 60 in--lb
(5.4 to 6.7 N--m)
25 ft--lb
(33 N--m)
9
UP
Note: The ports on the manifold(s) are marked for
easy identification of components. Example: S1 is a so-
lenoid valve and P3 is the gear pump connection port
(See Hydraulic Schematics to identify the function of the
hydraulic lines and cartridge valves at each port loca-
tion).
NOTE: The lift control manifold shown in Figure 50
uses a zero leak plug (item 12). This plug has a tapered
sealing surface on the plug head that is designed to re-
sistvibration inducedplug loosening.The zero leak plug
also has an o--ring to provide a secondary seal. If zero
leak plug removalis necessary, lightly rap the plug head
using a punch and hammer before using an allen
wrench to removethe plug:the impactw ill allow plug r e-
moval with lesschance of damage to thesocket head of
the p lug. When installing plug into the control manifold,
torque plug 25 ft--lb (33 N--m).