A SERVICE OF

logo

36
Chapter4SelfCalibration
4-2. Setting Monitor Date and Time
Set the monitor date and time.
Note
When ColorNavigator is started, the date and time are automatically set. For details, refer to the ColorNavigator User’s
Manual (on the CD-ROM).
Procedure
1. Choose “SelfCalibration” from the Adjustment menu, and press
.
2. Choose “Settings” from “SelfCalibration”, and press
.
3. Choose “Clock Adjustment” from “Settings”, and press
.
The Clock Adjustment menu appears.
4. Set date with or , and press .
5. Set time with
or , and press .
Attention
If the main power supply is disconnected for an extended period of time, the clock may need resetting.
4-3. Setting Calibration Schedule
Set the calibration schedule for SelfCalibration.
Procedure
1. Choose “SelfCalibration” from the Adjustment menu, and press
.
2. Choose “Settings” from “SelfCalibration”, and press
.
3. Choose “Schedule” from “Settings”, and press
.
The schedule setting menu appears.
4. Choose “Starting Time”, and press .
5. Set the “Starting Time” with
or .
Select the timing to execute SelfCalibration upon reaching the time set in the schedule.
Settings Function
Off SelfCalibrationisnotexecuted.
PowerSave
Tobeexecutedunderanyofthefollowingconditions.
• Whenthemonitorisin“PowerSave”modeorpowerisoffatthesettime.
• Themonitorshiftstothepowersavingmodeorthepoweristurnedoffwhen
thetimeperiodsetintheschedulehaselapsed.
Immediately SelfCalibrationisexecutedimmediatelyatthesettime.
Press to exit.
6. Choose “Setting Type, and press .
Select the method for setting the adjustment schedule.
Setting Function Setting Example
Type-1 Executeonceineveryfewmonths.
ExecuteonceamonthonWednesdayat1:00AM
oftherstweek.
Type-2 Executeonceineveryfewweeks.
ExecuteonceeveryfourweeksonWednesdayat
1:00AM.
Type-3
Executewhenthemonitorusagetime
exceedsthesettime.
Executewhenthemonitorusagetimeexceeded
200hours.
Press