Departmental Switch Model DS-16B Hardware Reference Manual
Error Messages
DIAG-ERRSTAT
Err#2640-2647, 3040-3047, 3840-3847
[portLoopbackTest, crossPortTest,
spinSilk]
Port Error Statistics counter is non-zero,
meaning an error was detected when
receiving frames.
One of the following status errors
occurred.
Enc_in – Encoding error, inside frame
CRC_err – Cyclic redundancy check on
frame failed
TruncFrm – Truncated frame
FrmTooLong – Frame too long
BadEOF – Bad end of file
Enc_out – Encoding error, outside frame
BadOrdSet – Bad symbol on fiber-optic
cable
DiscC3 – Discarded Class 3 frames
ASIC, mainboard,
GBIC module or
fiber cable failure
Replace
mainboard
assembly, GBIC
module or fiber
cable
DIAG-INIT
Err#264F, 304F, 384F
[portLoopbackTest, crossPortTest,
spinSilk]
Port failed to go active in the loopback
mode requested.
ASIC, mainboard,
GBIC module or
fiber cable failure
Replace
mainboard
assembly, GBIC
module or fiber
cable
DIAG-INTNIL
Err#2031
[cmiTest]
ASIC failed to get a CMI error (interrupt) ASIC failure Replace
mainboard
assembly
DIAG-INTNOTCLR
Err#102C
[centralMemoryTest]
The interrupt bit could not be cleared. ASIC failure Replace
mainboard
assembly
DIAG-LCMEM
Err#1027
[centralMemoryTest,
cmemRetentionTest]
Data read from the Central Memory
location did not match data previously
written into the same location
ASIC failure Replace
mainboard
assembly
DIAG-LCMEMTX
Err#1F27, 1028
[centralMemoryTest]
Central Memory transmit path failure:
ASIC 1 failed to read ASIC 2 via the
transmit path
mainboard failure Replace
mainboard
assembly
DIAG-LCMRS
Err#1F25, 1025
[centralMemoryTest,
cmemRetentionTest]
Central Memory Read Short: M bytes
requested but got less than M bytes
ASIC failure Replace
mainboard
assembly
Table C-3 Diagnostic Error Messages (continued)
Message Description Probable Cause Action