Installing the 2M46-04R
2M46-04R/2M46-04RDC User’s Guide 3-5
Figure 3-2 Attaching the Strain-Relief Bracket
There are two methods for attaching the rackmount brackets for the
2M46-04R and 2M46-04RDC. Proceed to the section entitled
Rackmounting the 2M46-04R for instructions on installing the
2M46-04R, or the section entitled Bonding the Rackmount Brackets to
the 2M46-04RDC, which discusses the GR-1089-CORE Section 9
bonding requirements for the 2M46-04RDC when installing rackmount
brackets.
Rackmounting the 2M46-04R
Proceed as follows to install the 2M46-04R into a 19-inch rack.
1. Remove and discard the four cover screws (two from each side)
located along the front edges of each side of the 2M46-04R.
2. Locate the four 6-32 x 3/8-inch flat head cover replacement screws in
the rackmount kit. Use these screws to attach the rackmount brackets
to the 2M46-04R as shown in Figure 3-3.
Strain-Relief Bracket
Screws (4)
2314-47
RESET
COM
HSIM 1HSIM 2
2M46-04R
21
PWR
CPU