Weider 15CT Home Gym User Manual


 
19
TROUBLE-SHOOTING AND MAINTENANCE
Make sure all parts are properly tightened each time you use the weight system. Replace any worn parts immedi-
ately. The weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use solvents.
TIGHTENING THE CABLES
Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is
slack in the cables before resistance is felt, the cables should be tightened.
Slack can be removed from the Short Cable (23) by
by tightening the 1/4” Nylon Locknut (2) at the end of
the Cable.
Additional slack can be removed by moving the 3 1/2”
Pulley (15) to the lower hole in the Long “U”-Bracket
(57). Remove the Cable Trap (66) and the Pulley from
the “U”-Bracket. Re-attach the Pulley and the Cable
Trap to the lower hole in the “U”-Bracket with the the
3/8” Nylon Locknut (21) and the 3/8” x 2” Bolt (12).
Make sure that the Cable Trap is in the proper
position and that the Cable and Pulley move
smoothly.
Note: If a cable tends to slip off the pulleys, the
cable may have become twisted. Remove the
cable and re-install it. If a cable needs to be
replaced, see ORDERING REPLACEMENT PARTS
on the back cover of this manual.
57
66
15
2
23
12
21