Suunto None Watch User Manual


 
the correct oxygen percentages are adjusted according to the measured oxygen
percentages in your cylinders
the oxygen partial pressure limits are set correctly
For more information on the NITROX mode, refer to Section 6.2. Diving in NITROX mode
(DIVEnitrox).
The dive computer is now ready for diving.
5.9.3. Battery power indication
Temperature or internal oxidation of the battery affect the battery voltage. If the instrument
is stored for a long period, or used in cold temperatures, the low battery warning may be
displayed even though the battery has enough capacity. In these cases, re-enter DIVE
mode to receive the battery power indication.
After the battery check, the Low Battery Warning is indicated by the battery symbol.
If the battery symbol is displayed in the Surface mode, or if the display is faded or weak,
the battery may be too low to operate the dive computer, and battery replacement is
recommended.
NOTE
For safety reasons, the backlight cannot be activated when the low
battery warning is indicated by the battery symbol.
5.9.4. Diving at altitude
The dive computer can be adjusted both for diving at altitude and also to increase the
conservatism of the mathematical nitrogen model.
When programming the instrument for the correct altitude, you need to select the correct
Altitude Adjustment settingsaccording to Table 5.4, AltitudeAdjustment settings. The dive
computer will adjust itsmathematical model according to the enteredaltitude setting, giving
shorter no-decompression times at higher altitudes (see Table 10.1, No-decompression
time limitsfor various depths(m) and Table 10.2,No-decompression time limitsfor various
depths (ft) in Section 10.2. RGBM).
Table 5.4. Altitude Adjustment settings
Altitude rangeAlt. adjustment value
0 - 300 m / 0 - 1000 ftA0
300 - 1500 m / 1000 - 5000 ftA1
1500 - 3000 m / 5000 - 10 000 ftA2
NOTE
Section 5.8.4. Setting the personal/altitude adjustments describes
how the Altitude value is set.
WARNING
Traveling to a higher elevation can temporarily cause a change in the
equilibrium of dissolved nitrogen in the body. It is recommended that
you acclimatize to the new altitude by waiting at least three hours
before diving.
23