ProForm PFTL591040 Treadmill User Manual


 
28
PROBLEM: One of the upper body arms squeaks during use
SOLUTION:
a.
Correcting this problem requires a small amount of
white marine grease, available at most hardware
stores. Turn the Resistance Knob (83) counterclock
-
wise until it can be removed. Remove the Resistance
Cone (89) and the Upper Body Arm (95), along with
the 3/8” Washers (84), Spring Washer (85), Thrust
Washers (86), and Thrust Bearing (87). (Note: If the
Resistance Sleeve [91] or Resistance Plate [88]
comes out of the Resistance Bracket [92] or
Resistance Cone, press it back in.) Apply a
thin layer
of white marine grease to the outer surface of the
Resistance Cone (89). Reattach all parts in the order
shown at the right.
PROBLEM: The incline of the treadmill does not change correctly or does not change when iFIT.com
CDs and videos are played
SOLUTION:a. With the key inserted in the console, press one of the Incline buttons. While the incline is
changing, remove the key. After a few seconds, re-insert the key. The treadmill will automati-
cally rise to the maximum incline level and then return to the minimum level. This will recalibrate
the incline system.
91
92
95
83
86
85
88
87
a
84
89