ProForm PFEXF495.0 Exercise Bike User Manual


 
MAINTENANCE AND TROUBLESHOOTmNG
inspect and tighten all parts of the exercise cycb reg-
ularly, Replace any worn parts immediately,
To clean the exercise cycb, use a damp cloth and a
small amount of mild detergent, important: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
BATTERY REPLACEMENT
if the consob display becomes dim, the batteries
should be replaced; most consob probbms are the
result of low batteries, To replace the batteries, see
assembly step 5 on page 7,
HOW TO ADJUST THE REED SWITCH
if the consob does not display correct feedback, the
reed switch should be adjusted, To adjust the reed
switch, the bft side shbld must be removed,
Turn the Crank (21) to the position shown, Using an
adjustable wrench, turn the Left Pedal (24) clockwise
and remove it, Next, remove the indicated M4 x
25mm Screws (42) and the indicated M4 x 16mm
Screws (49), Then, carefully remove the Left Side
Shield (17),
49
42
42
Next, locate the Reed Switch (43), Turn the Crank
(21) until the Magnet (38) is aligned with the Reed
Switch, Loosen, but do not remove, the indicated M4 x
16mm Screw (49), Slide the Reed Switch slightly clos-
er to or away from the Magnet, and then retighten the
Screw, Turn the Crank for a moment, Repeat until the
console displays correct feedback, When the Reed
Switch is correctly adjusted, reattach the left side
shield and the left pedal,
43
HOW TO LEVEL THE EXERCISE CYCLE
if the exercise cycle rocks on your floor during use,
see HOW TO LEVEL THE EXERCISE CYCLE on
page 9,
14