Newcon Optik NVS 14-3AGBW Hunting Equipment User Manual


 
12
Auto shut OFF at bright light
Each unit has a built-in high light sensor located near the IR
illuminator (2, Fig. 1). This sensor shuts the monocular off after
about 45 seconds of exposure to light exceeding 10
-1
lux.
To reset the monocular switch it off and then back on as
described in 6.3 and 6.2.
High-light shut-off feature does not mean that the Unit will react
to occasional flashes or bright spots. It protects the tube against
excessive light exposure only in order to avoid permanent
damage.
Auto-gating system
The NVS 14-3AG and NVS 14-3AGBW variants contain, in
addition to the systems described above, an auto-gated power
supply. This system automatically controls the power supplied to
the IIT in changing lighting conditions. This serves not only to
protect the IIT from exposure to bright lighting sources, but also
to automatically provide the user with the optimal image
regardless of prevailing light condition.