Newcon Optik NVS 10MG Binoculars User Manual


 
17
9. STORAGE
When preparing the unit for long-term storage, it is
necessary to perform corrosion proofing with a special
lubricant. Each 4 (four) years the lubricant should be
renewed to fully protect the device from corrosion. During
this operation the rest of previous lubricant coating should
be removed, and all metal surfaces should be degreased by a
cotton-wool cloth moistened in benzene. The new lubricant
coating should be applied after degreasing with a brush. The
plastic surfaces don’t require anti-corrosion coating.
When preparing for long-term storage the NVS 10MGs
received from the manufacturer or from the workshops, it is
necessary to check the completeness of equipment by
comparing what is available with the list of components in
the this document. The reliability of NVS 10 MG
attachments to weapon and parameters of adjustment by
azimuth and elevation should be checked with NVS 10MG
mounted on the weapon
When stored, the cases with NVS 10MGs should be placed
on stands, shelves or in cupboards at a dry, heated and
ventilated premise. The temperature at the premise shall be
between +5C and +35C, relative humidity — not more than
55% at temperature +25C.