Heath Zenith 9600LED series Camping Equipment User Manual


 
6
598-1338-03
Note: Whenrstturnedonwaitabout1
1
/
2
minutes
forthecircuitrytocalibrate.
*resetstoSecuritymodeatdawn.
OPERATION
Mode: On-Time Works: Day Night
Test
5Seconds x x
Security
5or10Minutes x
Automatic
Override
Dusk-to-Dawn x
Manual
Override
UntilDawn* x
MANUAL MODE
AUTO
TEST
ON-TIME Switch at 5 or 10
minutes
...backon.
1SecondOFF
then...
ManualOverridemodecanonly
be activated atnight whenthe
ON-TIMEswitchissettothe5
or10minuteposition.
Flipthelightswitchoffforonesec-
ondthenbackontochangefrom
SECURITY mode to MANUAL
OVERRIDEmode.
To return toSECURITY mode,
either:
•turnthelightoffforoneminute
thenturniton,or...
•daylightwillautomaticallyreset
thelighttoSECURITYmode.
MODE SWITCHING SUMMARY
Flip light switch off
for one second then
back on*
*Ifyougetconfusedwhileswitchingmodes,turn
thepoweroffforoneminute,thenbackon.Afterthe
calibrationtimethecontrolwillbeintheSECURITY
mode.
MANUAL OVERRIDE MODE
ADJUSTMENT OF COVERAGE AREA
Thesensoronthislightxturedetects“motion”bythe
movementofheatacrossthecoveragearea.However,
followingareexamplesofobjectsthatalsoproduce
heatandcancausethesensortotrigger:
•PoolsofWater •AirConditioners
•DryerVents •Animals
•HeatingVents •AutomobileTrafc
Ifyoususpectthataheatsourceofthistypeistrig-
geringthesensor,reducethesensitivity.
SPECIFICATIONS
Range ...........................Upto30ft.(9.1m)[varies
withsurroundingtempera-
ture].
SensingAngle ..............180°
ElectricalLoad ..............Upto 180WattMaximum
Tungsten Incandescent
or 5 Watt Maximum LED
(Lights of America model
2025LEDE12).
BulbType ......................E12 Candelabra Base,
Type“B”,60WattMaximum
TungstenIncandescent or
LEDmodel2025LEDE12
1.5Watt.
SensorCapacity ...........360Watt(3.0A)Maximum
TungstenIncandescent
PowerRequirements ....120VAC,60Hz
OperatingModes ..........TEST,SECURITY,AUTO-
MATIC OVERRIDE and
MANUALOVERRIDE
ON-Timer ......................5or10minutes
TestTimer .....................5Seconds
Automatic
OverrideTimer ..............Dusk-to-Dawn
Manual
OverrideTimer ..............UntilDawn
SECURITY
MODE