E
18
Specifications
Display ranges
Current speed S 0.0 (3.0) to 65.9 mile/h0
(27 inch)
±0.5 mile/h
(under 31 mile/h)
[0.0 (4.0) to 105.9 km/h]
Total distance O 0.0 to 99,999 mile [km] ±0.1 mile [km]
Maximum speed M 0.0 (3.0) to 65.9 mile/h ±0.5 mile/h
[0.0 (4.0) to 105.9 km/h]
Average speed A 0.0 to 65.9 mile/h [105.9 km/h] ±0.3 mile [km]
Trip distance D 0.00 to 999.99 mile [km] ±0.01 mile [km]
Elapsed time T 0:00’00" to 9:59’59" ±0.003%
12 hr. clock time 0:00' to 11:59' ±0.003%
Average heart rate AP 0 to 199 bpm ±1 bpm
Heart rate HR 0 (30) to 199 bpm ±1 bpm
If it exceeds 200 bpm, the third digit drops.
Calorie consumption
CAL 0.0 to 9,999.9 kcal Estimation
Controller: 4-bit 1-chip microcomputer (crystal controlled oscillator)
Display: Liquid crystal
Sensor: No-contact magnetic sensor
The length of the wire: 70cm
Transmitting system: Directional electromagnetic induction (Double pulse system)
Transmitting distance: About 80 cm
Power supply/service life: Main unit: Lithium battery (CR2032 x 1)
approx., 2 years (use time: 1 hr./day)
Wireless heart rate sensor: Lithium battery (CR2032 x 1)
approx. 2 years (use time: 1 hr./day)
Operating temperature range:
0 to 40˚C (32 to 104°F)
Storage temperature range: –20 to 50˚C (–4 to 122°F)
Applicable cycle sizes: 10 to 3,000 mm [Initial value: 2,155 mm]
Upper heart rate limit range: (lower limit) to 199 bpm [Initial value: 180 bpm]
Lower heart rate limit range: 0 to (Upper limit) [Initial value: 0 bpm]
Dimension/weight: Main unit:
1-29/32 x 1-13/16 x 7/8" [48.3 x 45.6 x 21.5 mm] / 1.16 oz [33 g]
Wireless heart rate sensor:
13 x 1-7/16 x 17/32" [330 x 36.5 x 13.5 mm] / 2.33 oz [66 g]
*The specification and deign are subject to change without notice.