Casio 5114 Watch User Manual


 
Operation Guide 5114 5214
E-104
Thermometer:
Measurement and display range: –10.0 to 60.0 °C (or 14.0 to 140.0 °F)
Display unit: 0.1 °C (or 0.2 °F)
Measurement timing: Every fi ve seconds in the Barometer/Thermometer Mode
Other: Calibration; Manual measurement (button operation)
Altimeter:
Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference altitude
Display range: –10,000 to 10,000 m (or –32,800 to 32,800 ft.)
Negative values can be caused by readings produced based on a reference altitude or due to
atmospheric conditions.
Display unit: 5 m (or 20 ft.)
Current Altitude Data: 5-second intervals for 1 hour (
0’05
), or 5-second interval for fi rst 3 minutes
followed by 2-minute interval for next 10 hours (
2’00
)
Altitude Memory Data:
Manual save records: 14 (altitude, date, time)
Auto save values: High altitude (with month, day, time of reading), low altitude (with month, day,
time of reading), cumulative ascent (with month, day, time of fi rst reading), cumulative descent
(with month, day, time of fi rst reading)
Other: Reference altitude setting; Altitude graph; Altitude differential; Altitude auto measurement
method (
0’05
or
2’00
)
Bearing Sensor Precision:
Direction: Within ±10°
Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
North indicated by second hand: Error of ±2° for each mark in the scale.
E-105
Pressure Sensor Precision:
Conditions (Altitude) Altimeter Barometer
Fixed
temperature
0 to 6000 m
0 to 19680 ft.
± (altitude differential × 2%
+ 15 m) m
± (altitude differential × 2%
+ 50 ft.) ft.
± (pressure differential × 2%
+ 2 hPa) hPa
± (pressure differential × 2%
+ 0.059 inHg) inHg
6000 to 10000 m
19680 to 32800 ft.
± (altitude differential × 2%
+ 25 m) m
± (altitude differential × 2%
+ 90 ft.) ft.
Effect of
variable
temperature
0 to 6000 m
0 to 19680 ft.
± 50 m every 10 °C
± 170 ft. every 50 °F
± 5 hPa every 10 °C
± 0.148 inHg every 50 °F
6000 to 10000 m
19680 to 32800 ft.
± 70 m every 10 °C
± 230 ft. every 50 °F
Values are guaranteed for a temperature range of –10 °C to 40 °C (14 °F to 104 °F).
Precision is lessened by strong impact to either the watch or the sensor, and by temperature extremes.
Temperature Sensor Precision:
±2°C (±3.6 °F) in range of –10 °C to 60 °C (14.0 °F to 140.0 °F)
Stopwatch:
Measuring unit: 1/100 second
Measuring capacity: 59' 59.99"
Measuring modes: Elapsed time, split time, two fi nishes
Countdown Timer:
Measuring unit: 1 second
Countdown start time setting range: 60 minutes (1-minute unit)
E-106
Alarms:
5 Daily alarms; Hourly time signal
World Time:
29 cities (29 time zones)
Other: Daylight Saving Time/Standard Time; Home City/World Time City switching
Illumination:
LED (light-emitting diode); Selectable illumination duration (approximately 1.5 seconds or 3
seconds); Auto Light Switch on/off (Full Auto LED Light lights only in the dark)
Other:
Battery power indicator; Power Saving; Low-temperature resistance (–10 °C/14°F); Button
operation tone on/off; Hand home position auto adjustment; Time Formats (12-hour and 24-hour)
Power Supply:
Solar cell and one rechargeable battery
Approximate battery operating time: 5 months (from full charge to Level 4) under the following
conditions:
Watch not exposed to light
Internal timekeeping
Display on 18 hours per day, sleep state 6 hours per day
1 illumination operation (1.5 seconds) per day
10 seconds of alarm operation per day
10 compass operations per week
10 hours of altimeter measurement, once per month
Barometric pressure readings and graph updating every two hours (12 times per day)
4 minutes of signal reception per day
Frequent use of illumination runs down the battery. Particular care is required when using the auto
light switch (page E-94).
L-1
City Code Table
City
Code
City
UTC Offset/
GMT Differential
PAGO PAGO (PPG) Pago Pago –11
HONOLULU (HNL) Honolulu –10
ANCHORAGE (ANC) Anchorage –9
LOS ANGELES (LAX) Los Angeles –8
DENVER (DEN) Denver –7
CHICAGO (CHI) Chicago –6
NEW YORK (NYC) New York –5
SANTIAGO (SCL) Santiago –4
RIO
Rio De Janeiro
–3
PRAIA (RAI) Praia –1
UTC
0
LONDON (LON) London
PARIS (PAR) Paris +1
ATHENS (ATH) Athens +2
JEDDAH (JED) Jeddah +3
TEHRAN (THR) Tehran +3.5
DUBAI (DXB) Dubai +4
City
Code
City
UTC Offset/
GMT Differential
KABUL (KBL) Kabul +4.5
KARACHI (KHI) Karachi +5
DELHI (DEL) Delhi +5.5
KATHMANDU (KTM) Kathmandu +5.75
DHAKA (DAC) Dhaka +6
YANGON (RGN) Yangon +6.5
BANGKOK (BKK) Bangkok +7
HONG KONG (HKG) Hong Kong +8
TOKYO (TYO) Tokyo +9
ADELAIDE (ADL) Adelaide +9.5
SYDNEY (SYD) Sydney +10
NOUMEA (NOU) Noumea +11
WELLINGTON (WLG) Wellington +12
Based on data as of July 2010.
The rules governing global times (GMT
differential and UTC offset) and summer time
are determined by each individual country.