TWO HOUR TEMPERATURE OVER-
RIDE — Press or until the display
shows the temperature you want. The ther-
mostat will override current programming
and keep the room temperature at the se-
lected temperature for two hours. After two
hours, the thermostat will automatically re-
vert to the program.
HOLD TEMPERATURE — The thermostat
can hold any temperature within its range
for an indefinite period, without reverting to
the program. Press
HOLD
COPY
. HOLD will be
displayed. Then choose the desired hold
temperature by pressing or . The
thermostat will hold the room temperature
at the selected setting until you press
RUN
PRGM
to start program operation again. This fea-
ture is ideal for energy conservation when
the building is unoccupied for an extended
period of time.
°F/°C CONVERTIBILITY — Press
TIME
FWD
and
TIME
BACK
at the same time until the tem-
perature display is in °C (Celsius). To dis-
play °F, repeat the process.
ADJUSTABLE HEATING AND COOLING
CYCLE TIMES (ANTICIPATION) — If the
heating/cooling system is turning on and off
too often (short cycles) or not often enough
(long cycles), you may want to adjust the
anticipation setting.
A cooling anticipation setting of less
than 10 may cause decreased compres-
sor life.
CAUTION
!