A SERVICE OF

logo

R
December 16, 2011
7014-179D
Page11
CB 1200 Pellet Stove
Do not terminate ventinanyenclosedorsemi-enclosed
areasuchasacarport,garage,attic,crawlspace,undera
sundeckorporch,narrowwalkwayorcloselyfencedarea,
oranylocationthatcanbuildupaconcentrationoffumes
suchasastairwell,coveredbreezeway,etc.
CAUTION
A. Chimney and Exhaust Connection
1. Chimney & Connector:Use3or4inch(76-102mm)
diametertype"L"or"PL"ventingsystem.Itcanbevented
verticallyorhorizontally.
2. Mobile Home: ApprovedforallListedpelletvent.Ifusing
the3inch(76mm)verticaltopventadapterkitorthe3
to6inch(76-152mm)topventoffsetadapter,useListed
doublewallueconnector.AQuadra-Fireoutsideairkit
mustbeusedwithmanufacturedhomeinstallations.
3. Residential: The3inch(76mm)verticaltopventadapter
kitandthe3to6inch(76-152mm)topventoffsetadapter
aretestedtouse24gaugesinglewallueconnectoror
ListeddoublewallueconnectortoClassAListedmetal
chimneys,ormasonrychimneysmeetingnationaland/or
localcodesforsolidfuelappliances.
4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
5. Secureexhaustventingsystemtotheappliancewithatleast
3screws.Alsosecureallconnectorpipejointswithatleast
3screwsthrougheachjoint.
6. DONOTINSTALLAFLUEDAMPERINTHEEXHAUST
VENTINGSYSTEMOFTHISUNIT.
7. DONOTCONNECTTHISUNITTOACHIMNEYFLUE
SERVINGANOTHERAPPLIANCE.
NOTE: All pipe must be welded seam pipe whenever pos-
sible. Seal pipe joints with high temperature silicone (500°F
[260°C] minimum rated only). Do not put silicone inside
of pipe.
NOTE: If burning shelled eld corn, you must use approved
venting specically designed for corn. Follow the instruc-
tions from the venting manufacturer.
FireHazard.
• OnlyLISTEDventingcomponentsmaybe
used.
• NOOTHERventcomponentsmaybeused.
Substituteordamagedventcomponentsmay
impairsafeoperation.
WARNING
B. Venting Termination Requirements
1. Terminationmustexhaustaboveairinletelevation.Itis
recommendedthatatleast60inches(1524mm)ofverti-
calpipebeinstalledwhenapplianceisventeddirectly
throughawall.Thiswillcreateanaturaldraft,which
willhelppreventthepossibilityofsmokeorodorventing
intothehomeduringapoweroutage.Itwillalsokeep
exhaustfromcausinganuisanceorhazardbyexposing
peopleorshrubstohightemperatures.Thesafestand
preferredventingmethodistoextendtheventvertically
throughtheroof.
2. Distancefrom doorsandopeningwindows,orgravityor
ventilationairinletsintobuilding:
a. Notlessthan48inches(1.2m)below;
b. Notlessthan48inches(1.2m)horizontallyfrom;
c. Notlessthan12inches(305mm)above.
3. Distancefrompermanentlyclosedwindows:
a. Notlessthan12inches(305mm)below,horizontally
fromorabove.
4. Distancebetween bottomofterminationandgrade
shouldbe12inches(305mm)minimum.Thisiscon-
ditionaluponplantsinthearea,andnatureofgrade
surface.Thegradesurfacemustbeanon-combustible
material(i.e.,rock,dirt).Thegradesurfacemustnotbe
lawn.Distancebetweenbottomofterminationandpublic
walkwayshouldbe84inches(2134mm)minimum.
5. Distancetocombustible materialsmustbe24inches
(610mm)minimum.Thisincludesadjacentbuildings,
fences,protrudingpartsofthestructure,roofoverhang,
plantsandshrubs,etc.
6. TerminationCapLocation(HomeElectricalService)
• Side-to-sideclearanceistobethesameasminimum
clearancetovinylinsidecorners.
•
Clearanceofaterminationcapbelowelectricalservice
shallbethesameasminimumclearancetovinylsofts.
• Clearanceofaterminationcapaboveelectricalservice
willbe12inches(305mm)minimum.
• Locationoftheventterminationmustnotobstructor
interferewithaccesstotheelectricalservice.
4
Vent Information
VentsurfacesgetHOT,cancauseburnsif
touched.Noncombustibleshieldingorguards
mayberequired.
WARNING