Preparation for extraction
^ When using C 150 mm ducting,
secure the exhaust connection
supplied to exhaust ducting with
hose clips.
^ If using C 125 mm ducting, fit the
reducing collar into the exhaust
connection, and secure the exhaust
ducting to the reducing collar with a
hose clip. (See "Connection for air
extraction").
^
Place the exhaust ducting on the fan
connection for the cooker hood.
^
See "Connection for air extraction" for
further instructions on fitting the
ducting.
^
DA 2210: The hood has two exhaust
connections for use with two 150 mm
diameter exhaust hoses.
A Y- adapter is supplied with the
hood. It may be used to feed the
exhaust from both connections to a
200 mm diameter common duct.
Installation
29