Installation (for qualified installers only) 15
© Travis Industries 4090717 100-01225_000
Horizontal Termination with One 90° Elbow
If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
19' max (5.8m)
0 feet
5 feet (1.5m)
0 feet
0 feet
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
Restrictor Position # 5
NOTE:
Restrictor positions are based
upon lab tests. The ideal
restrictor position may vary
slightly, especially when the
termination is near a
demarkation line.
Restrictor
Position # 1
10 feet (3m)
15 feet (4.5m)
20 feet (6m)
24 ' max (7.3m)
0 feet
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
20 feet (6m)
24 ' max (7.3m)
19' max (5.8m)
NOTE:
Horizontal sections require a 1/4" (0.250mm)
rise every 12" (305mm) of travel.
NATURAL GAS: Min. 2' (0.61m) Section Required
PROPANE (LP): Min. 3' (0.915m) Section Required