A SERVICE OF

logo

10 Installation (for qualified installers only)
© Travis Industries 4090717 100-01225_000
Optional Wall Switch or Thermostat Installation
Do not connect 110-120 VAC to the gas control valve or wiring system of this stove. The switch must
be installed by a qualified installer.
This stove may be installed with an optional wall switch or thermostat. The thermostat (or on/off switch)
wires will interrupt the burner circuit (see item “a” below).
1. If you wish to bypass the switch, connect the thermostat (on/off switch) wires directly to the green and
white wires (see “b” below).
2. If you wish keep the switch (series) – re-align the wires as shown in item “c” below. NOTE: The
on/off switch must be in the “ON” position for the thermostat (or on/off switch) to operate.
COMFORT
CONTROL
AA
BATTERY
TRAY
MAIN
BURNER
Red
Red
Black
White
Green
Black
Red
Red
Blue
Red
Blue
Black
POWER SUPPLY
ON / OFF
a
b
Burner Circuit Wires
Bypass
White
Green
Thermostat or
On/Off Switch
White
Green
Thermostat or
On/Off Switch
Series
c