![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/30/4308d02c-7e56-45cc-8b8d-79a9cf5f958f/4308d02c-7e56-45cc-8b8d-79a9cf5f958f-bg41.png)
Replacing Consumables
65
f Resetting the lamp operating time
The projector records how long the lamp is turned on and a message and
indicator notify you when it is time to replace the lamp. After replacing
the lamp, make sure you reset the lamp hours from the configuration
menu. s p.41
Replacing the Air Filter
f Air filter replacement period
It is time to replace the air filter when:
• The air filter has been turned brown by such things as tobacco
resin.
• When the message "The air filter is clogged. Clean or replace the
air filter." is frequently displayed, even though the air filter has
been cleaned.
f How to replace the air filter
The air filter can be replaced even when the projector is suspended from a
ceiling.
A
After you turn off the projector's power and the
confirmation buzzer beeps twice, disconnect the
power cable.
B
Open the air filter cover.
While pushing the air filter cover catches, pull the cover down.
Attention
• Make sure you install the lamp securely. If the lamp cover is
removed, the lamp turns off automatically as a safety precaution.
If the lamp or the lamp cover is not installed correctly, the lamp
does not turn on.
• This product includes a lamp component that contains mercury
(Hg). Please consult your local regulations regarding disposal or
recycling. Do not dispose of it with normal household waste.
q
Only reset the lamp operating time after the lamp has been
replaced, otherwise the lamp replacement period is not
indicated correctly.
Procedure