![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/ce/9ce727af-9272-4266-a814-9782c91c22d1/9ce727af-9272-4266-a814-9782c91c22d1-bg27.png)
1-29
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
OL-8787-05
• Amber indicates that the following warning condition exists:
–
A single fan rotation failure at less than 4000 RPM or greater than 10950 RPM.
• Red indicates a possible problem, including:
–
The fan tray is not responding to commands for configuration and temperature-related
operations.
–
A fan is not responding to commands for temperature and speed related operations.
–
The fan speed has fallen below the minimum allowed RPM for a fan.
Power Supply LEDs
Each SFS 7012 power supply has two LEDs: DC OK and AC OK. Following are the statuses for each.
DC OK
–
Green indicates that DC power is normal.
–
Off indicates a DC power failure or no DC power is present.
AC OK
–
Green indicates that AC power is normal.
–
Off indicates a AC power failure or no AC power is present.
SFS 7012 Leaf and Spine Module LEDs
Leaf Module IB Port LEDs
Each SFS 7024 leaf module port has a Blue IB link status LED that provide the following indications:
• On - the logical link is up (port is in the Active state).
• Off - the physical link is down (port is in the Down state).
Spine and Leaf Module Status LED
The status LED indicates one of the following conditions:
• Steady Green - the module is operating normally.
• Blinking Green - LED test state.
• Off - module is in the removable state.
Spine and Leaf Module Attention LED
The Attention LED indicates one of the following conditions:
• Off - the system functioning normally.
• Steady Amber - the system requires some attention, which could indicate one of the following
conditions:
–
The switch temperature is at a warning level on the module.
–
The switch silicon temperature is at a warning level (approximately 90 degrees C).
–
DC voltages on the board are slightly out of tolerance (12V Bulk, 5V, 3.3V, 1.8V, VBIO are all
monitored).