-26-
Revision 4/F3591 © Moffat Ltd, August 2004
Injection
Nozzle
3) Pull the fan and motor assembly into the
oven as pictured below, and disconnect
the wiring. The fan motor unit can now be
removed from the oven.
4) Slacken the two socket head grub screws
spaced at 90
o
on the fan boss.
Figure 6.3.14
5) Remove the fan from the motor shaft.
NOTE:
Use of a fan puller is recommended
for removal of the oven fan.
6) Re-assemble in the reverse order.
NOTE:
No lubrication of either the fan or
motor is required as they are both self
lubricating.
Figure 6.3.15
6.3.12 CONTACTOR
1) Remove R/H side panel (refer 6.2.4).
2) Disconnect wires from the contactor
(noting their positions).
3) Remove contactor from the mounting
bracket.
4) Replace contactor and re-assemble in
reverse order.
Figure 6.3.16
1) Remove the fan baffle (refer 6.2.2).
2) Unscrew the water injection nozzle.
3) Clean or replace nozzle, and reassemble
in reverse order.
6.3.14 WATER INJECTION NOZZLE
Figure 6.3.19
6.3.13 ELEMENTS
Contactor
3) Remove the fan baffle (refer 6.2.2)
4) Remove the three screws securing the
element mounting plate to the wall of the
oven.
5) Withdraw the element assembly. Replace
the faulty element, and reassemble in
reverse order.
NOTE:
The correct resistance of each E1100
element is 16 ohms ± 5%.
Figure 6.3.17
Figure 6.3.18
Element plate
1) Remove the oven right hand side panel
(refer 6.2.4).
2) Remove the wires from the element
assembly.