3 Wire Positive Switched Door Lock/Unlock Wiring Detail
15
3 Wire Positive Switched Door Locks:
In this application, the Red wire of the two pin harness provides a + 12 volt pulse during the disarming
sequence, or pulsed 12 volt unlock output. Connect the Red wire to the low current 12 volt signal wire
from the factory door unlock switch to the factory door unlock relay.
The Green wire of the two pin harness provides a + 12 volt pulse during the arming sequence, or pulsed
12 volt lock output. Connect the Green wire to the low current 12 volt signal wire from the factory door
lock switch to the factory door lock relay. See Below For Wiring Detail.
Note: For connection to Four Wire Polarity Reversal, 5 Wire Alternating 12 Volts, And All Other Door
Lock Circuits the Audiovox AS-9159 Door Lock Interface, (or equivalent 30 A automotive relays)
must be used. Refer to the Audiovox Door Lock Wiring Supplement for proper wiring of these
circuits.
ALARM SELECTABLE FEATURES
NOTE:The Alarm Selectable Features and Remote Start Selectable Features programming steps
following are based on transmitter button 1 being programmed for channel 1 and transmitter
button 2 being programmed for channel 2.
RF Programmable Features:
Feature Selection 1 Chirp 2 Chirps 3 Chirps Default
First 1 Second Door Locks 3.5 Second Door Lock 1 Second L/Dbl. Unlock 1 Second
Second Auto Lock On Auto Lock Off Auto Lock Off
Third Auto Unlock On Auto Unlock Off Auto Unlock Off
Fourth Passive Door Locks Active Door Locks Active Door Locks
Fifth Passive Arming Active Arming Passive Arming