Weider WESY37531 Home Gym User Manual


 
TROUBLESHOOTING
Inspect and tighten all parts each time the weight system is used. Replace any worn parts immediately. The
weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use solvents.
TIGHTENING THE CABLES
Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is
slack in the cables before resistance is felt, the cables should be tightened.
To tighten the cables, first insert the weight pin into the middle of the weight stack. Slack can be removed from
these cables several ways:
See drawing 1. Loosen the 1/2” Plain Nut (45) on the Weight
Cable (72) bolt, away from the 1/2” Flat Washer (11). Screw
the bolt a few turns into the Weight Tube (17). Retighten the
1/2” Plain Nut down onto the 1/2” Flat Washer.
See drawing 2. Remove either the upper or lower 3/8” Nylon
Locknut (50) and 3/8” x 2” Bolt (54) from the Adjustable
Pulley Plates (23). Remove the 3 1/2” Pulley (24) and the
Cable Trap (25). Reattach the 3 1/2” Pulley and the Cable
Trap to a hole closer to the center of the Adjustable Pulley
Plates with the 3/8” x 2” Bolt and 3/8” Nylon Locknut.
Either set of Adjustable Pulley Plates (23) can be adjust-
ed in this manner.
Do not overtighten the cables. If the cables are over tightened, the top weight will be lifted off the weight
stack. If a cable tends to slip off the pulleys often, it may have become twisted. Remove the cable and
re-install it.
If the cables need to be replaced, see ORDERING REPLACEMENT PARTS on the back cover of this manual.
24
11
23
54
72
17
50
24
45
25
2
1