True Fitness 750R Bicycle User Manual


 
Symptom Probable Cause Corrective Action Recommended Tools
NO CONTACT
HEART RATE
750U, 750R
Dirty Sensors
Console Set/
Wiring
Wire Connections
Verify hand pulse sensors are clean.
--------
Set meter for continuity.
Remove Console set.
Check for continuity in both sets of
hand pulse sensors between the console
set and hand pulse sensor plates.
If continuity is OK – Replace Console
set. If no- continue on.
--------
Check wire connections @ handlebar
console mast joint
Check connections of wires to hand
pulse sensor by removing hand pulse
sensor plates.
To remove hand pulse sensor plates
carefully pry under one end to free them
from the plastic handgrips.
Bad connections? - Reconnect/ Replace
bad wires.
Recheck continuity.
Note:
You must pedal at least
30 RPM when
p
erforming any voltage
test. You may require the
assistance of another
p
erson when performing
volta
g
e checks.
Multi-meter
Double sided tape
Support Services 800-883-8783 Mon-Fri 8:30am-5:00pm Central Time Zone Fax: 636-272-7148
Page 15