True Fitness 600R Bicycle User Manual


 
Symptom Probable Cause Corrective Action Recommended Tools
NO RPM
READING
500R, 500U
Control Panel/ RPM
Sensor
Defective Cables
Defective RPM
Sensor Set
Disconnect 5PA from 5PB. Set meter to
check continuity between 2 and 5 of
5PB. (See Page 18)
Turn pedals slowly, check continuity
between 2 and 5 of 5PB.
Does continuity change from off to on?
If yes – cables and sensor are good –
Replace Control Panel.
If no – Go to Defective RPM Set.
When the sensor is over the
pickup, continuity will exist.
When sensor is not over pickup,
cicuit will be open.
--------
Perform continuity checks on all upper
and lower cables.
Replace defective cables.
--------
If cables OK- Replace RPM sensor set.