True Fitness 600R Bicycle User Manual


 
Symptom Probable Cause Corrective Action Recommended Tools
No Display
750U, 750R
Console Set
Brake
Defective Cable
Console Cable/
Lower Control
Board
Remove console set bolts. Verify good
connection at the back of the console
set. Set meter for DC volts
Pedal.
Measure between #1 and #4 wires (Page
21) for 5.5 – 7.5 VDC.
Is required voltage present?
If yes- replace console set. If not,
continue on.
--------
Remove pedal and if 3 piece crank
remove crank arm.
Remove right side cover.
Disconnect 3- wire connector at brake.
Set meter for AC volts.
Pedal.
The voltage should increase as pedaling
increases.
Is minimum voltage 9 VAC @ 30
RPM?
If No- replace Brake. If yes, continue
on.
--------
Remove pedal and if 3 piece crank
remove crank arm.
Remove right side cover.
Disconnect 3- wire cable from brake and
lower control board.
Set meter for continuity.
Check all 3 wires in cable for continuity.
No continuity? Replace cable
----------
Set meter for DC volts. Reconnect
cable to brake and lower control board.
Pedal.
Measure for 5.5 – 7.5 VDC between #1
and #4 wires on 7- pin cable for the
console at the lower control board.
Voltage is present? Replace cable for
console.
Voltage not present? Replace lower
control board.
Note:
You must pedal at least
30 RPM when
p
erforming any voltage
test. You may require the
assistance of another
p
erson when performing
volta
g
e checks.
Multi-meter
Support Services 800-883-8783 Mon-Fri 8:30am-5:00pm Central Time Zone Fax: 636-272-7148
Page 14