True Fitness 350-750 Treadmill User Manual


 
Symptom Probable Cause Corrective Action Recommended Tools
SPEED
FLUCTUATION
E2: CAL
Speed Fluctuation
(Due to high friction)
Speed Fluctuation
(Due to Voltage
fluctuation)
Bad Data Feedback
Incorrect Speed
Sensor Gap
Perform Push Off Test (page 24)
Perform Amp Draw Test (page 20)
--------
Check Line voltage for fluctuations.
Have customer take corrective action.
--------
Verify tach feedback accuracy through
out the speed range.
If inaccurate perform speed sensor test
(page 21)
--------
Verify correct Speed sensor Gap.
Gap should be equal to the thickness of
(3) credit cards pressed together
(approximately 1/8 to ¼ inch)
------
Multi-meter
Socket Set
Silicone Lubrication
Packet
Silicone Lubrication
Applicator
Note: All
trouble shootin
g
should be
performed in
Calibration
Mode:
See SG-12
Support Services 800-883-8783 Mon-Fri 8:30am-5:00pm Central Time Zone Fax: 636-272-7148
Page 10