Sears 831.287627 Home Gym User Manual


 
MAINTENANCE AND "I ROUBLE-SHOOTING
Inspect and tighten all parts of the CARDIO FIT at least every three months. Keep the monitor out of direct
sunlight or the LCD display may be damaged. The monitor can be cleaned using a soft, dry cloth. Do not allow
liquid to come in contact with the monitor. Remove the batteries when storing the CARDIO FIT.
REPLACING THE BA'I-rERIES
Ifthe display of the Monitor (1) becomes dim, the two L1154
watch batteries should be replaced. Remove the #8 x 1/2"
Screw (16) from the back ofthe Monitor. Remove the two
screws from the back cover of the Monitor and remove the
back cover. Push the two old batteries out of theclips, and
insert two new batteries.
Reattach the back cove_,and reattach the Monitor (1) to the
Frame (6). Make sure that the wire on the Monitor isplugged
intothe sensor wire; Insert any excess wire into the Frame.
Make sure not to pinch the wire between the Frame and the
Monitor.
ADJUSTING THE MAGNET AND REED SWITCH
Ifthe monitor does not function properly,the Magnet (27) and
Reed Switch (15) should be checked. Pivot the Pedal Frame
(7) until the Magnet is aligned with the Reed Switch. Loosen
the #8 x 3/4" Screw (33) and adjust the positionof the Reed
Switch so that there is a 1/8" gap between the Magnet and
the Reed Switch. Retighten the Screw.
LUBRICATING THE CARDIO FIT
The ends of the Unk Arms (4) should be oiled every six
months. Apply a few drops of light multi-purpose oilbetween
the LinkArms and the dome caps inthe indicated locations.
Apply Oil II
8