Reebok Fitness RBTL19605.0 Treadmill User Manual


 
25
PROBLEM: The walking belt slows when walked on
S
OLUTION: a
. Use only a single-outlet surge suppressor that meets all of the specifications described on page 10.
b
. If the walking belt is overtightened, treadmill perfor-
mance may decrease and the walking belt may be
permanently damaged. Remove the key and
UN-
PLUG THE POWER CORD. Using the included hex
key, turn both rear roller bolts counterclockwise 1/4 of
a turn. When the walking belt is properly tightened,
you should be able to lift each edge of the walking
belt 3 to 4 inches off the walking platform. Be careful
to keep the walking belt centered. Then, plug in the
power cord, insert the key, and run the treadmill for a
few minutes. Repeat until the walking belt is properly
tightened.
c. If the walking belt still slows when walked on, please see the front cover of this manual.
PROBLEM: The walking belt is off-center or slips when walked on
SOLUTION:
a. If the walking belt is off-center, first remove the key
and UNPLUG THE POWER CORD. If the walking
belt has shifted to the left, use the hex key to turn
the left rear roller bolt clockwise 1/2 of a turn; if the
walking belt has shifted to the right, turn the bolt
counterclockwise 1/2 of a turn. Be careful not to over-
tighten the walking belt. Then, plug in the power cord,
insert the key, and run the treadmill for a few minutes.
Repeat until the walking belt is centered.
b. If the walking belt slips when walked on, first remove
the key and
UNPLUG THE POWER CORD. Using
the hex key, turn both rear roller bolts clockwise 1/4
of a turn. When the walking belt is correctly tightened,
you should be able to lift each edge of the walking
belt 3 to 4 inches off the walking platform. Be careful
to keep the walking belt centered. Then, plug in the
power cord, insert the key, and walk on the treadmill
for a few minutes. Repeat until the walking belt is
properly tightened.
PROBLEM:
T
he chest pulse sensor does not function properly
SOLUTION:
a. If the chest pulse sensor does not function properly, see CHEST PULSE SENSOR TROUBLE-
SHOOTING on page 9.
b. If the chest pulse sensor still does not function properly, the battery
should be changed. To replace the battery, locate the battery cover
on the back of the sensor unit. Insert a coin into the slot in the cover
and turn the cover counterclockwise to the “open” position. Remove
the cover.
Next, remove the old battery from the sensor unit. Insert a new CR
2032 battery, making sure that the writing is on top. In addition, make
sure that the rubber gasket is in place in the sensor unit. Replace the
battery cover and turn it to the closed position.
Rear Roller Bolts
b
3
–4"
a
b
Battery
Rubber
Gasket
b
Battery
Cover