ProForm PFTL93105.0 Treadmill User Manual


 
PROBLEM: The walking belt is off-center or slips when walked on
S
OLUTION: a
.
I
f the walking belt is off-center,
f
irst remove the key and
UNPLUG THE POWER CORD. If the walking belt has
s
hifted to the left,
u
se the allen wrench to turn the left
rear roller bolt clockwise 1/2 of a turn;
if the walking belt
has shifted to the right, turn the bolt counterclockwise
1/2 of a turn. Be careful not to overtighten the walking belt.
Then, plug in the power cord, insert the key, and run the
treadmill for a few minutes. Repeat until the walking belt is
centered.
b.
If the walking belt slips when walked on, first remove
the key and UNPLUG THE POWER CORD. Using the
allen wrench, turn both rear roller bolts clockwise 1/4 of a
turn. When the walking belt is correctly tightened, you
should be able to lift each edge of the walking belt 3 to 4
inches off the walking platform. Be careful to keep the
walking belt centered. Then, plug in the power cord, insert
the key, and walk on the treadmill for a few minutes.
Repeat until the walking belt is properly tightened.
PROBLEM: The display of the console does not function properly
SOLUTION: a. Remove the key from the console and UNPLUG THE
POWER CORD. Next, remove the screws from the hood
and carefully remove the hood. Locate the Reed Switch
(17) and the Magnet (12) on the left side of the Pulley (11).
Turn the Pulley until the Magnet is aligned with the Reed
Switch. Make sure that the gap between the Magnet
and the Reed Switch is about 1/8”. If necessary, move
the Reed Switch slightly using a slotted screwdriver.
Reattach the hood and run the treadmill for a few minutes
to check for a correct speed reading.
PROBLEM: The chest pulse sensor does not function properly
SOLUTION: a. If the chest pulse sensor does not function properly, see CHEST
PULSE SENSOR TROUBLESHOOTING on page 8.
b. If the chest pulse sensor still does not function properly, the battery
should be changed. To replace the battery, locate the battery cover
on the back of the sensor unit. Insert a coin into the slot in the cover
and turn the cover counterclockwise to the “open” position. Remove
the cover.
Remove the old battery from the sensor unit. Insert a new
CR 2032
battery, making sure that the writing is on top. In addition, make sure
that the rubber gasket is in place in the sensor unit. Replace the bat-
tery cover and turn it to the closed position.
b
23
12
17
Top
View
1/8”
11
a
a
Battery
Rubber
Gasket
Battery Cover
b
Battery
Cover