ProForm PCTL69030 Treadmill User Manual


 
TROUBLESHOOTING
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and
follow the steps listed. If further assistance is needed, please call our Customer Service Department toll-
free at 1-888-936-4266, Monday through Friday, 8h00 until 18h30 eastern time (excluding holidays).
PROBLEM: The power does not turn on
SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppres-
sor is plugged into a properly grounded outlet (see page 7). Use only a CUL-listed surge sup-
pressor, rated at 15 amps, with a 1 mm
2
(14-gauge) cord of 1.5 m (5 ft.) or less in length.
b. After the power cord has been plugged in, make sure that the key is fully inserted into the console.
c. Check the circuit breaker located on the treadmill
frame near the power cord. If the switch protrudes
as shown, the circuit breaker has tripped. To reset
the circuit breaker, wait for five minutes and then
press the switch back in.
PROBLEM: The power turns off during use
SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see the drawing
above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.
b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for
five minutes, and then plug it back in.
c. Remove the key from the console. Reinsert the key fully into the console.
d. If the treadmill still will not run, call our Customer Service Department, toll-free.
PROBLEM: The displays of the console do not function properly
SOLUTION: a. Check the batteries in the console. If the batteries need to be replaced, see BATTERY
INSTALLATION on page 8. Most problems are the result of drained batteries.
b. Remove the key from the console and UNPLUG THE POWER CORD. Remove the screws from
the hood, and carefully remove the hood.
Locate the Reed Switch (44) and the Magnet (45) on
the left side of the Pulley (50). Turn the Pulley until
the Magnet is aligned with the Reed Switch. Make
sure that the gap between the Magnet and the
Reed Switch is about 3mm (1/8 in.). If necessary,
loosen the Screw (33) and move the Reed Switch
slightly. Retighten the Screw. Re-attach the hood, and
run the treadmill for a few minutes to check for a cor-
rect speed reading. Reattach the Resistance Knob.
Tripped
Reset
Tripped
Reset
c
45
44
33
Top
View
3mm
50
12
b