• Mount an antenna discharge unit
as close as possible to where the
lead-in enters the facility.
• Use a jumper wire not smaller than
No. 6 AWG (13.3mm
2
) copper or
the equivalent when a separate
antenna-grounding electrode is
used. See NEC Section 810-21 (j).
Note to CATV system installer: This
reminder is provided to call the CATV
system installer’s attention to Article
820-40 of the NEC that provides guide-
lines for proper grounding and, in par-
ticular, specifies that the cable ground
shall be connected to the grounding
system of the building, as close to the
point of cable entry as practical.