Casio 2872 Watch User Manual


 
Operation Guide 2872
9
xxx is shown on the display while calibration is being performed. When
calibration is complete, the Digital Compass Mode screen (showing the
angle value) appears.
If
xxx appears and then changes to
Err
(error) on the calibration screen,
it means that there is something wrong with the sensor.
Err
will disappear
after about one second. Press A to return to the Digital Compass Mode
screen, and then try performing the calibration operation again. If
Err
keeps appearing, contact your original dealer or nearest authorized CASIO
distributor to have the watch checked.
To perform northerly calibration
1. While in the Digital Compass Mode, hold
down A until
x1x appears on the display,
which indicates the setting screen.
2. Press C to start the northerly calibration
procedure.
At this time,
-N- (north) appears on the
display.
l
l
l
l
l
l
l
l
l
l
3. Place the watch on a level surface, and position it so that its 12 o’clock
position points north (as measured with another compass).
4. Press B to start the calibration operation.
xxx is shown on the display while calibration is being performed. When
calibration is complete, the Digital Compass Mode screen (with
0
°
indicated as the angle value) appears.
If
xxx appears and then changes to
Err
(error) on the calibration screen,
it means that there is something wrong with the sensor.
Err
will disappear
after about one second. Press A to return to the Digital Compass Mode
screen, and then try performing the calibration operation again. If
Err
keeps appearing, contact your original dealer or nearest authorized CASIO
distributor to have the watch checked.
Changing the Barometric Pressure and Temperature Units
Changing the barometric pressure units automatically restarts display of the
barometric pressure indicators.
To change the barometric pressure and temperature units
1. Press E to enter the Barometer/
Thermometer Mode.
2. Hold down A until
OFF appears or until the
display goes blank. This is the setting screen.
If the display goes blank, it means there is
calibration value. Release A. Wait for four
or five seconds and the value will appear.
3. Press C to move the flashing in the sequence
shown below.
4. Use C to move the flashing to the unit setting you want to change
(
°C/°F or hPa/inHg).
5. Press D to select the unit you want.
6. Press A to return to the Barometer/Thermometer Mode screen.
l
l
l
l
l
l
l
l
l
l
l
l
Temperature
Sensor
Calibration
Pressure
Sensor
Calibration
°C / °F
hPa/inHg
Calibrating the Temperature Sensor
The temperature sensor of this watch is calibrated at the factory before
shipment, and further adjustment is normally not required. If you notice
serious errors in the temperature readings produced by the watch, you can
calibrate the sensor to correct the errors.
Important!
Incorrectly calibrating the temperature sensor can result in incorrect readings.
Carefully read the following before doing anything.
Compare the readings produced by the watch with those of another reliable
and accurate thermometer.
If adjustment is required, remove the watch from your wrist and wait for 20
or 30 minutes to give the temperature of the watch time to stabilize.
To calibrate the temperature sensor
1. Press E to enter the Barometer/
Thermometer Mode.
2. Hold down A until
OFF appears or until the
display goes blank. This is the setting screen.
If the display goes blank, it means there is
calibration value. Release A. Wait for four
or five seconds and the value will appear.
3. Press D (+) or B (–) to change the displayed
temperature by 0.1°C (or 0.2°F).
Pressing B and D at the same time
returns to the factory calibration (
OFF).
4. Press A to return to the Barometer/
Thermometer Mode screen.
l
l
l
l
l
l
l
l
l
l
l
l
Calibrating the Barometric Pressure Sensor
The pressure sensor of this watch is calibrated at the factory before shipment
and further adjustment is normally not required. If you notice serious errors in
the barometric pressure readings produced by the watch, you can calibrate
the sensor to correct the errors.
Important!
Incorrectly calibrating the barometric pressure sensor can result in incorrect
readings. Before performing the calibration procedure, compare the readings
produced by the watch with those of another reliable and accurate barometer.
To calibrate the pressure sensor
1. Press E to enter the Barometer/
Thermometer Mode.
2. Hold down A until
OFF appears or until the
display goes blank. This is the setting screen.
If the display goes blank, it means there is
calibration value. Release A. Wait for four
or five seconds and the value will appear.
3. Press C to move the flashing to the
barometric pressure calibration status in the
center of the display.
At this time,
OFF or the barometric
pressure value should be flashing on the
display.
4. Press D (+) or B (–) to change the displayed
barometric pressure by 1 hPa (0.05 inHg).
Pressing B and D at the same time
returns to the factory calibration (
OFF).
5. Press A to return to the Barometer/
Thermometer Mode screen.
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
To change the altitude unit
1. Press D to enter the Altimeter Mode.
2. Hold down A until
OFF (flashing) appears or until the display goes blank.
This is the setting screen.
If the display goes blank, it means there is a reference altitude value.
Release A and wait for four or five seconds until the value appears.
3. Press C to move the flashing to the altitude
unit setting.
4. Use D to select the unit you want (m or ft).
5. Press A to return to the Altimeter Mode
screen.
Performing the above procedure causes
altitude values stored in memory also to be
converted to the unit you select.
l
l
l
l
l
l
l
l
l
l