A SERVICE OF

logo

5
INSTALLER/CONFIGURATION MENU
With Heat or A/C selected, press and hold the Menu button for at least 5 seconds. The display will show item #1 in the
table below. Press Menu to advance to the next menu item. Press
or to change a menu item options.
INSTALLER/CONFIGURATION MENU
Menu
Ref.
HP SS Press
Button
Displayed
(Factory Default)
Press
or to
select from listed op-
tions
Comments
1 1 1 MENU (MS 2) HP 1, HP 2, SS 1 Selects Multi-Stage (MS 2 No Heat Pump),
Heat Pump 1 (HP 1, 1 compressor),
Heat Pump 2 (HP 2, 2 compressor or 2 speed
compressor), or Single Stage (SS 1)
2 2 2 MENU (GAS) for SS or MS
(ELE) for HP1, HP2
ELE or GAS GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
3 3 3 MENU (On) E OFF Selects Energy Management Recovery (EMR)
On or OFF. (Not available in -non-program-
mable mode)
4 4 MENU (ME) Cr Heat SL, FA Selects Adjustable Anticipation, cycle rate, Heat
(This item only appears when MS 2 or SS 1 is
selected above)
5 4 MENU (ME) Cr Heat A/C SL, FA Selects Adjustable Compressor Anticipation
(Heat Pump) this item only appears when
HP 1, HP 2 is selected above
6 5 5 MENU (ME) Cr A/C
or
(FA) Cr Aux Heat
SL, FA
SL
Selects Adjustable Anticipation, cycle rate, cool
(when MS 2 or SS 1 is selected above) or
Selects the cycle rate for Auxiliary stage (when
HP 1 or HP 2 is selected above)
7 6 6 MENU (OFF) CL On Selects Compressor Lockout Off or On
8 7 7 MENU Heat A/C Off
or
Aux Heat A/C Off
Heat A/C Off,
Heat Off with Fan icon,
Heat Off without Fan icon
A/C Off
System Mode Configuration
9 8 8 MENU (OFF) CO On Selects Compressor Optimization
10 9 9 MENU (On) dL OFF Selects Display Light On or OFF
11 10 10 MENU 0 HI
(current temperature)
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
12 11 11 MENU °F
(current temperature)
°C Selects Fahrenheit/Celsius Temperature Display
13 12 12 MENU (0) P 7 Defaults to P (0) non-programmable
P (7) is 7-day programming
14 13 13 MENU PS (2)
Day, Night
4
Morn, Day, Eve, Night
Selects Program periods per day:
4 = Morn, Day, Eve, Night
2 = Day, Night
(Skipped if non-programmable)
15 14 MENU (On) Heat FA OFF Fast Heat option may be disabled by
selecting OFF. NA to SS or HP1 config.
16 15 14 MENU (On) FA A/C OFF Fast Cool option may be disabled by
selecting OFF. NA to SS or HP1 config.
17 16 15 MENU (On) dS Off Selects Automatic Daylight Saving Time option
18 17 16 MENU (99) HL Heat 62 to 98 Select's Limited HEAT Range
19 18 17 MENU (45) LL A/C 46 to 82 Select's Limited A/C Range
20 19 MENU (0) dF 1 to 9 Selects dF (Dual Fuel) setting. 0 is Off
(If Dual Fuel option is required, a selection of 5
is recommended)
MENU (60) Cd 0 to 99 Selects compressor delay in seconds when dF
is greater than 0
21 20 18 MENU (o) A/C On Heat (b) Selects operation of the reversing valve terminal
(O/B) output as an O or B terminal
22 21 19 MENU Returns to Normal Operation