Power indicator is
on; Data indicator
is off
The Ethernet cable may not be connected properly to the unit's
Ethernet port. Check this connection on both units.
Data light blinking This is normal. It means the units are transferring/receiving data.
Power indicator
on; Link and Data
indicators don’t
light
Make sure both units are plugged directly into unswitched, non-
GFI outlets. Do not plug them into a surge protector.
The units may be too far from each other. Try moving them to
outlets that are closer together.
Power, Link, and
Data indicators on;
no video or audio
on display
Make sure your TV is on.
Make sure your TV is switched to the correct input for the HDP50.
Check the Ethernet connection between the HDP50 unit and your
TV. Make sure both ends are firmly connected.
Try a different Ethernet cable.
Power, Link, and
Data indicators on;
frozen or no video
on display
The units may be too far from each other. Try moving them to
outlets that are closer together
Static/Interference Move units away from halogen lamps, light dimmers, and surge
protectors—these types of electronics can cause static.
PHY Rate
200Mbps
Effect Data Rate
TCP: Up to 75 Mbps effective throughput
UDP: Up to 90 Mbps effective throughput
Frequency Band
2~28 MHz (With Mask)
Access Methods
CSMA/CA channel-access schemes
Qos
Four-level priority based contention access, and multi
segment bursting
8-levels VLAN priority field, TOS Field
QoS Classification by destination MAC address and IP Port
Modulation
OFDM (QAM 8/16/64/256/1024, QPSK, BPSK, ROBO)
Standards
IEEE 802.3, IEEE 802.3U, HomePlug AV1.1
Nodes
Up to 63 slaves with 1 master, 64 total devices
4 overlapping networks for neighbor networks with CCo
failover
Up to 4 masters with up to 252 slaves, 256 total devices in
4 AVLNs
Max 64 bridged devices per station
Up to 4096 addressable devices including bridged devices
Specifications