Page 14
7014-083C
October 26, 2006
CB1200-I Pellet Insert
5
Venting Systems
Figure 14.2
A. Direct Connect With Outside Air
B.
Direct Connect Without Outside Air
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B65.
Outside Air
through
Rear Wall
Figure 14.1
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
•
Factory-built chimney must be 6 inch (152mm)
UL10 HT.
WARNING
CAUTION
Never draw outside combustion air from:
• Wall, oor or ceiling cavity
• Enclosed space such as an attic or garage
NOTE:
• Illustrations reect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
NOTE; Use metal plate
around exhaust vent pipe
and seal all edges with
non-ammable insulation
such as berglass, mineral
wool or ceramic material.
Do not use high tempera-
ture caulking materials to
seal any edge to prevent
future serviceability.
NOTE: In Canada, only a full reline is
allowed per ULC S-628, ORD ULC C1482.