![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/e7/de7b02e4-3ce2-4cf5-94c8-9a48ab469ed6/de7b02e4-3ce2-4cf5-94c8-9a48ab469ed6-bg3e.png)
All plumbing work should be carried
out by a suitably qualified and
competent person, in accordance
with all applicable local and national
regulations.
The water quality must conform to
country requirements for drinking
water.
–
The appliance is only suitable for
connection to the cold water supply.
– The water pressure must be between
25 and 120 psi (1.72-8.25 bar).
– A separate shut-off valve must be
installed, so that the water supply
can be interrupted as needed.
– The maximum outer diameter of the
water pipe (without fittings):
3
/
8
" (10 mm).
The shut-off valve for the water
connection must not be located
behind the appliance. It is
recommended to place the shut-off
valve directly next to the appliance
(base unit) or in another easily
accessible location.
Plumbing
62