STORING DATA IN PM CHANNELS
1 Confirm that the following conditions have been
satisfied:
• The transceiver is in the receive mode.
• Scan is not being used.
• The Microphone Control is OFF.
2 Configure the transceiver as you like.
• For the items that can be stored, see page 41.
3 Press [PM], [P.IN].
• PM channel numbers 1 to 5 appear and blink at the
bottom of the display.
4 Press [1] to [5] corresponding to your desired PM
channel.
• The settings listed on page 41 are stored in the PM
channel.
• Press [OFF] to cancel.
RECALLING A PM CHANNEL
1 Press [PM].
• PM channel numbers 1 to 5 appear at the bottom of the
display.
2 Press [1] to
[5] corresponding to your desired PM
channel.
• The contents of the selected PM channel are recalled.
• The recalled PM channel number appears in the upper
right corner.
• To exit PM Recall mode, press [PM], then press [OFF].
Note: You cannot recall a PM channel while transmitting.
AUTO PM CHANNEL SAVE
After you recalled a PM channel, the function
automatically overwrites the current PM channel with the
present operating environment when:
• You recall another PM channel.
• You press [OFF] in PM channel recall mode.
• You switch the transceiver OFF.