Troubleshooting (continued)
If all the lights on the User Interface are Off
and there is no response from the cooktop,
complete the following steps:
1. Disconnect power.
2. Check the continuity between L2 on the
terminal block and both L2 terminals on
theEMIlterboard.Ifthereisno
continuity on one or both of these 2
lines, change the thermofuse harness
that is blown.
3. Replace all parts and panels before
operating.
4. Reconnect power.
5. Check that it is working. If it is not, go to
Step 6.
6. Disconnect power.
7. Check the continuity of the fuses on the
EM I b o a r d . I f o n e o r m o r e o f t h e f u s e s i s
blown, replace with a new fuse.
8. Replace all parts and panels before
operating.
9. Reconnect power.
10. Check that it is working. If it is not, go
to Step 11.
11. Disconnect power.
12. Change both control boards.
13. Replace all parts and panels before
operating.
14. Reconnect power.
15.Recongurethecooktopfollowing
thedirectionsin“ManualConguration
Mode.”
16. Check that it is working. If it is not, go
to Step 17.
17. Disconnect power.
18. Change the User Interface.
19. Replace all parts and panels before
operating.
20. Reconnect power.
21.Recongurethecooktopfollowing
thedirectionsin“ManualConguration
Mode."
Failure/Error Codes