![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/d4/2d4c8f63-d12b-4222-8784-987243750030/2d4c8f63-d12b-4222-8784-987243750030-bg15.png)
OM-201 444 Page 17
3-10. Remote Amperage Control Receptacle
1
2
1 Remote Amperage Control
Receptacle RC1
2 Keyway
To connect remote amperage con-
trol to receptacle, insert plug and
turn clockwise until tight.
Ref. ST-800 040
3-11. Electrical Service Guide
50 Hertz Models 500 Amp Model
Input Voltage 220 380 440
Input Amperes At Rated Output 103 60 51
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay
2
100 60 50
Normal Operating 3 125 70 60
Min Input Conductor Size In AWG/Kcmil 4 8 8
Max Recommended Input Conductor Length In Feet (Meters)
193
(59)
258
(79)
346
(105)
Min Grounding Conductor Size In AWG/Kcmil 6 8 10
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).