Engineering Guideline EH-150 Series PLC
Analog Input Modules
5
0 to 10V (V) / -10 to 10V (H)
Less than +/-1% (full scale)
Less than +/-1% (full scale)
-50°C to 400°C (PT100) - -
+/-3% (-50°C to 400°C), +/-
-50°C to 400°C (PT1000) - - +/-6% (-50°C to 400°C)
Channel - internal circuit
Current inputs *1)
4 Channels/module
- -
Voltage inputs *1)
4 Channels/module
8 Channels/module
-
PT100/PT1000 - - 4 Channels/module
Removable type
Removable type
Removable type
24V DC (+20%, -15%, approx.
24V DC (+20%, -15%, approx.
24V DC (+/-10%,
*1): Both current inputs and voltage inputs are available at the same time.
External connection
Temperature-sensing element
No. of channels
Measuring range
and accuracy
Input impedance
Insulation system
External power supply (Module supply
Internal current consumption (5V)
Analog Output Modules
0 to 10V -10 to 10V
0 to 10V (V) / -10 to 10V
Channel - internal circuit
Voltage outputs *3
2 Channels/module
2 Channels/module
4 Channels/module
Current outputs *3
2 Channels/module
- -
*3: Both current outputs and voltage ouputs are available at the same time.
External power supply (Module supply
Insulation system
No. of channels
Internal current consumption (5V)
External load
Ouput voltage range
Less than +/-1% (full scale)
Removable type screw terminal block
24V DC (+20%, -15%, approx. 150mA)