
Page | 15
FLOORPROTECTION
Thispelletstoverequiresanon‐combustiblefloorprotectorifthestoveistobeinstalledon
acombustiblefloor.Ifthefloorthestoveistobeinstalledonisalreadynon‐combustible
(i.e.aconcretefloorinabasement)andhasanRvalueequaltoor
higherthan.2,nofloor
protectionisneeded(althoughadecorativefloorprotectorcanstillbeusedforaesthetic
reasons).
PrefabricatedfloorprotectorswhichareULlistedorequivalentcanbepurchasedorafloor
protectorcanbebuiltfromstandardmaterials;twosheetsof.5”thickcementboard
covered
withceramictilewouldbeasuitablefloorprotectorwhichmeetsthe.2R‐value
requirement.
Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduce
heatingandcoolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortar
andgroutjoints.AhearthrugisNOTanapprovedsubstituteforaproperhearthpad.
FortheUS:Thefloorprotectormustextendatleast6in.(152.4mm)fromthefront&sides
and4in.(101.6mm)fromtherear.
ForCanada:Thefloorprotectormustextendatleast18.0in.(457.2mm)fromthefrontof
theunit,8.0in.(203.2mm)fromthesidesoftheunitand4.0in.(101.6mm)fromtherear.
InCanada,itisrequiredthatthenon‐combustiblefloorprotectorisunderneathand
extends2in.(50.8mm.)oneithersideofanyhorizontalventingrunsAND/ORisdirectly
underneathanyverticalventingpipe.
US:6.0in.
US:6.0in.
n
:
.
in.
US:4.0in.
n
:4.
in.
US:6.0in.
n
:1
.
in.