-26-
After replacing the Power Board, PF.C. Board, readjust
the Output voltage adjustment as follows.
1. Connect a digital voltmeter to pins 1 (+) and 3 (-) of
K6D.
2. Adjust the voltage by using VR611 as following.
A
C Input Reading
230V 370V ±2V
or 120V 340V ±2V
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
● Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the follow-
ing adjustments except requiring the readjustments in servicing otherwise it may cause loss of per-
formance and product safety.
[Adjustment Condition]
● Input signal
Video signal .......................... 1.0Vp-p/75Ω terminated, 16 steps gray scale (Composite video signal)
Computer signal...................... 0.7Vp-p/75Ω terminated, 16 steps gray scale pattern (XGA)
● Picture control mode ...................... “STANDARD” mode unless otherwise noted.
Note:
* Please refer to “Service Adjustment Menu Operation” for entering to the service mode and adjusting the service
data.
Electrical Adjustments
Output Voltage adjustment
1. Receive the 16-step grey scale video signal.
2. Set to VIDEO mode.
3. Enter the service mode.
[R-PEDESTAL ADJUSTMENT]
4. Connect an oscilloscope to test point “TP201R”(+)
and chassis ground (-).
5. Select group no. “3”, item no. “14” and change data
value to adjust the pedestal level and black level to be
the same level.
[G-PEDESTAL ADJUSTMENT]
6. Connect an oscilloscope to test point “TP201G”(+)
and chassis ground (-).
7. Select group no. “3”, item no. “15” and change data
value to adjust the pedestal level and black level to be
the same level.
[B-PEDESTAL ADJUSTMENT]
8. Connect an oscilloscope to test point “
TP201B”(+)
and chassis ground (-).
9. Select group no. “3”, item no. “16” and change data
value to adjust the pedestal level and black level to be
the same level.
Pedestal adjustment
1. Enter the service mode and select group no. “11” and
item no. “0”. Set data value to “1”.
2. Connect a digital voltmeter to test point “TP12V1” (+)
and chassis ground (-). Select item no.“1” and change
data value to adjust voltage to be 8.0 ±0.1V.
3. Connect a digital voltmeter to test point “TP12V2” (+)
and chassis ground (-). Select item no. “2” and
change data value to adjust voltage to be 9.0 ±0.1V.
4. Select group no. “11” and item no. “0” and set data
value to “3”.
5. Connect a digital voltmeter to test point “TP12V1” (+)
and chassis ground (-). Select item no.“3” and change
data value to adjust voltage to be 13.0 ±0.1V.
6. Connect a digital voltmeter to test point “TP12V2” (+)
and chassis ground (-). Select item no.“4” and change
data value to adjust voltage to be 13.5 ±0.1V.
Fan Voltage adjustment