![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/71/97138e97-c862-423d-bb85-5e359a61bdaf/97138e97-c862-423d-bb85-5e359a61bdaf-bgf.png)
14
Please check and clean the air lter periodically. When the indicators or a message
prompts you to clean the air lter, comply with it as soon as possible. The air lter has two
kinds of lters inside. Replace the lters when they are damaged or too soiled. To prepare
the new lters, make contact with your dealer and tell the following type number.
Type number : MU06481 (Filter set)
When you replace the lamp, please replace the air lter. An air
lter of specied type will come together with a replacement
lamp for this projector.
1.
Turn the projector off, and unplug the power cord. Allow the
projector to sufciently cool down.
2.
Use a vacuum cleaner on and around the lter cover.
3.
While supporting the projector with one hand, use your
other hand to pull the lter cover forward in the direction of
the arrow.
4.
Use a vacuum cleaner for the lter vent of the projector
and the outer side of the lter unit.
5.
Take the lters out while holding the lter cover.
6.
Use a vacuum cleaner onto the both sides of the lters.
When vacuuming up the ne meshed lter, hold it so it
will not be sucked in. If the lters are damaged or heavily
soiled, replace them with the new ones.
7.
Put the lters back into the lter cover. Put the coarse
meshed lter into a lter cover rst. Then put the ne
meshed lter on the coarse meshed one, turning its stitched
side up.
8.
Put the lter unit back into the projector.
9.
Turn the projector on and reset the lter time using the
FILTER TIME item in the EASY MENU.
(1) Press the MENU button to display a menu.
(2) Point at the FILTER TIME using the ▼/▲ button, then
press the ► button. A dialog will appear.
(3) Press the ► button to select “OK” on the dialog. It
performs resetting the lter time.
Cleaning and replacing the air lter
WARNING ►Before taking care of the air lter, make sure the power cable
is not plugged in, then allow the projector to cool sufciently.
►
Use only the air lter of the specied type. Do not use the projector without the
air lter or the lter cover. It could result in a re or malfunction to the projector
.
►
Clean the air lter periodically. If the air lter becomes clogged by dust or the like,
internal temperatures rise and could cause a re, a burn or malfunction to the projector.
NOTE • Please reset the lter time only when you have cleaned or replaced
the air lter, for a suitable indication about the air lter.
• The projector may display the message such as “CHECK THE AIR FLOW” or
turn off the projector, to prevent the internal heat level rising.
Filter cover
Filter unit
Filter cover
Filter (ne meshed)
Filter (coarse meshed)
2
4
3
7
Stitched
side