A SERVICE OF

logo

www.desatech.com
119162-01A 23
INSPECTING bURNERS
Check pilot ame pattern and burner ame pat-
terns often.
pILOT FLAME pATTERN
Figure 35 shows a correct pilot ame pattern.
Figure 36 shows an incorrect pilot ame pattern.
The incorrect pilot flame is not touching the
thermocouple. This will cause the thermocouple
to cool. When the thermocouple cools, the heater
will shut down.
If pilot ame pattern is incorrect, as shown in
Figure 36
turn heater off (see To Turn Off Gas to Appli-
ance, page 21
see Troubleshooting, page 25
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue and
have no yellow or orange color.
Figure 35 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 36 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner

Figure 36 shows correct front burner ame pat-
tern. Figure 37 shows incorrect front burner ame
pattern. The incorrect burner ame pattern shows
yellow tipping at top of blue ame.

-


   



Figure 37 - Correct Front Burner Flame
Pattern
Figure 38 - Incorrect Front Burner Flame
Pattern





If front burner ame pattern is incorrect, as shown
in Figure 37
turn heater off (see To Turn Off Gas to Appli-
ance, page 21)
see Troubleshooting, page 25
Yellow Tipping At
Top of Blue Flame
WIRING DIAGRAM
To
Thermopile
To AUTO/OFF/ON
Switch or Remote
Receiver