INSTALLING THE SPINDLE
1. Remove the spindle from its package.
2. Follow the machine’s safety and installation instructions.
3. Clamp the spindle to the machine - using 5 screws (M6 or 1\4” UNF socked head – minimal
length 15 mm).
8
4. Remove plugs from water, air and brushes ventilation connections (5).
5. Connect inlet air pipe Ø6 mm to “AIR IN” (AI).
6. Connect outlet air pipe Ø5 mm to “AIR OUT” (AO).
7. Connect inlet water pipe Ø8 mm to “WATER IN” (WI).
8. Connect outlet water pipe Ø8 mm to “WATER OUT” (WO).
9. Connect
Ø 4 mm pipe to brushes ventilation hole (BV).
10. Remove black plastic nut from the end of the shaft.
11. Turn air supply on, spin the shaft by hand and make sure that the shaft is rotating freely.
12. Check for air pressure ( 4.5-5.5 [bar].)
13. Check for airflow ( 35-55 [lpm].)
14. Connect signal cable to the driver.
15. Connect power cable to the driver
16. Connect brushes cable to the spindle.
17. Open water pressure on to derivate water leaks.
18. Check for water pressure (4-5 bar)
19. Check for water flow (2.5 – 3.5 [lpm])
20. Turn the driver on and spin the spindle. Start at low speed (5000 rpm for 5 minutes) and slowly
increase up to 60 Krpm.
21. Check for motor current at 5000 rpm, less 0.5 Amp.