![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/5b/05bde7fb-f8cb-4ff4-95dd-c654be6c69da/05bde7fb-f8cb-4ff4-95dd-c654be6c69da-bg38.png)
4-4
Cisco ME 4924-10GE Ethernet Switch Hardware Installation Guide
OL-10071-01
Chapter 4 Troubleshooting
Troubleshooting the Hardware Components
Getting Started
When the initial system boot is complete, verify the following:
• Power supplies are supplying power to the system.
• The system fan assembly is operating.
• System software boots successfully.
If all of these conditions are met and the hardware installation is complete, refer to the Software
Configuration Guide and the Command Reference publications to troubleshoot the software. However,
if any of these conditions are not met, use the procedures in this chapter to isolate and, if possible,
resolve the problem.
Problem Solving to the System Component Level
The key to success when troubleshooting the system is to isolate the problem to a specific system
component. The first step is to compare what the system is doing to what it should be doing. Because a
startup problem can usually be attributed to a single component, it is more efficient to isolate the problem
to a subsystem rather than troubleshoot each separate component in the system.
The switch consists of the following subsystems:
• Power supply—Includes the power supply and power supply cooling. (See the “Troubleshooting the
Power Supply” section on page 4-6.)
• Fan assembly system—The chassis fan assembly should operate whenever system power is on.
Usually, it continues to operate even when the environmental monitor shuts down the system
because of an overtemperature or overvoltage condition. (It will shut down for a power supply
shutdown.) You should be able to hear the fan assembly to determine whether or not it is operating.
If the FAN LED is orange and you determine that the fan assembly is not operating, you should
immediately contact a customer service representative. There are no installation adjustments that
you can make if the fan assembly does not function properly at the initial startup.
Identifying Startup Problems
When you connect the power cords to the Cisco ME 4924-10GE, follow these steps:
Step 1 Flip the power switches to the on position (AC powered systems only ).
Step 2 Verify that power is available to the power supplied from the site AC or DC source. Flip breakers and
fuses if necessary.
Step 3 Listen for the system fan assembly. If you do not immediately hear the system fan assembly begin to
operate, see “Troubleshooting the Power Supply” section on page 4-6.
Step 4 If you determine that the power supplies are functioning normally and that the fan assembly is faulty,
contact a customer service representative. If the system fan assembly does not function properly at initial
startup, there are no installation adjustments that you can make.