4-2
The functions of the System Status (SMB and CPU) LEDs are listed in Table 4-1.
The status of the INB Receive LED is listed in Table 4-2.
The status of the INB Transmit LED is listed in Table 4-3.
Table 4-1. System Status (SMB and CPU) LEDs
LED Color State Description
Green Functional Fully operational
Yellow/Green Booting Blinks yellow and green while booting
Yellow Testing Performing power-up testing
Yellow (Flashing) Crippled Not fully operational (i.e., one bad port)
Red Reset Normal power-up reset
Red (Flashing) Failed Fatal error has occurred
Off No Power No power is being supplied to the module
Table 4-2. INB Receive LED
LED Color State
Green Link exists, no activity, port is enabled
Yellow (Flashing) Link exists, activity, port is enabled
Red No link, port is disabled
Red (Flashing) Link exists, port is disabled
Off No link, no activity, port is enabled
Table 4-3. INB Transmit LED
LED Color State
Green (Flashing) Activity, port is enabled
Yellow (Flashing) Port is in standby mode
Red Port is disabled
Red (Flashing) Fault or error exists