![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/83/083d29f8-8f99-411f-bfd6-9cb87e15f307/083d29f8-8f99-411f-bfd6-9cb87e15f307-bgb5.png)
171
Data Ports
Applicator Interface Connector
1/11/07 T408M/T408M-R User Guide 14178L-001 Rev. A
6 REPRINT Input • If the Reprint feature is enabled, this input must be
asserted LOW to cause the printer to reprint the last
label.
• If the Reprint feature is disabled, this input is ignored.
7+28V
(Fused at 500 mA.)
Caution • Replace
the fuse only with
one of the same
type and rating.
Power The Interface Power Supply. Supplies power to external
sensors as required.
Note • If operating with 28V signals only, pin 7
may be used to supply power to pin 2, which
creates a non-isolated mode of operation.
8 POWER GROUND
(+28 V DC Return)
Ground The Interface Power Ground.
Note • If pin 7 is used to supply power to pin 2,
use this pin to ground pin 1.
9
10 SERVICE
REQUIRED
Output Asserted LOW in the following circumstances:
• the media cover is open
• the printhead is open
• the ribbon or media is out
• the printer is paused
• an operational fault occurs
• a Resynch error occurs while the applicator Resynch
mode is set to Error mode
11 END PRINT Output • MODE 0—The applicator port is OFF.
• MODE 1—Asserted LOW only while the printer is
moving the label forward; otherwise deasserted HIGH.
• MODE 2—Asserted HIGH only while the printer is
moving the label forward; otherwise deasserted LOW.
• MODE 3—(Default) Asserted LOW for 20
milliseconds when a label is completed and positioned.
Not asserted during continuous printing.
• MODE 4—Asserted HIGH for 20 milliseconds when a
label is completed and positioned. Not asserted during
continuous printing.
12 MEDIA OUT Output Asserted LOW while there is no media in the printer.
Table 20 • Applicator Interface Connector Pin Configuration (Continued)
Pin
No.